By Series:
T.S. 0
| Drawing Number | Drawing | Drawing Name | Date |
| 0-1 | | Standard Abbreviations | May 2015 |
| 0-2 (1/3) | | Plan Symbols | January 2012 |
| 0-2 (2/3) | | Plan Symbols | January 2012 |
| 0-2 (3/3) | | Plan Symbols | January 2012 |
| 0-3 (1/2) | | Standard Definitions | March 2010 |
| 0-3 (2/2) | | Standard Definitions | March 2010 |
| 0-4 | | Reference Documents and General Requirements | April 2019 |
T.S. 1
| Drawing Number | Drawing | Drawing Name | Date |
| 1-1 (1/2) | | Light Duty - Light Weight No. 5 and No. 7 Pull Box | September 2011 |
| 1-1 (2/2) | | Light Duty - Light Weight No. 5 and No. 7 Slope Wall Body Pull Box Details | September 2011 |
| 1-2 | | Heavy Duty No. 5 and No. 7 Straight Body Wall Pull Box Details | March 2015 |
| 1-3 | | Replacement Lid Sizing for Existing No. 5 and No. 7 Pull Boxes | September 2011 |
| 1-4 (1/3) | | Typical Pull Box Installation and Wiring Details | September 2011 |
| 1-4 (2/3) | | Typical Pull Box Installation and Wiring Details | September 2011 |
| 1-4 (3/3) | | Typical Pull Box Installation Details | September 2011 |
| 1-5 (1/2) | | Electrical Conduit Cover and Trench Requirements | September 2011 |
| 1-5 (2/2) | | Conduit Expansion Couplings | September 2011 |
| 1-6 | | Conductor Requirements | September 2011 |
| 1-7 | | Traffic Signal IMSA Cable Color Codes | March 2010 |
| 1-8 (1/2) | | Front of Barrier Junction Box | September 2011 |
| 1-8 (2/2) | | Back of Barrier Junction Box | September 2011 |
| 1-9 | | Top of Barrier Junction Box Details | September 2011 |
| 1-10 | | Top of Barrier Junction Box Details | September 2011 |
| 1-11 (1/3) | | Heavy Duty Lighting No. 4 and No. 6 Pull Box | October 2013 |
| 1-11 (2/3) | | Heavy Duty Lighting No. 4 and No. 6 Pull Box | October 2013 |
| 1-11 (3/3) | | Heavy Duty Lighting No. 4 and No. 6 Pull Box Lid | March 2015 |
| 1-12 (1-2) | | Precast Heavy Duty Lighting No. 4B and No. 6B Pull Box | March 2015 |
| 1-12 (2-2) | | Precast Heavy Duty Lighting No. 4B and 6B Pull Box | March 2015 |
T.S. 2
| Drawing Number | Drawing | Drawing Name | Date |
| 2-1 | | Foundation for Type II Load Center Cabinet | March 2010 |
| 2-2 | | Foundation for Type IV Load Center Cabinet | March 2010 |
| 2-3 | | Foundation for Type III Control Cabinet | March 2010 |
| 2-4 | | Foundation for Type IV, V Control Cabinets | March 2010 |
| 2-5 | | Type A Foundation for 340 Controller Cabinets | March 2010 |
| 2-6 | | Meter Pedestal Cabinet Foundation and Base | March 2010 |
| 2-7 | | Traffic Signal UPS Cabinet Foundation Detail | March 2015 |
T.S. 3
| Drawing Number | Drawing | Drawing Name | Date |
| 3-0 | | Notes for Type II and IV Load Center Cabinets | December 2012 |
| 3-1 | | Type II Load Center Cabinet | March 2010 |
| 3-2 | | Type IV Load Center Cabinet | March 2010 |
| 3-3 | | Type II Load Center Cabinet Wiring Details 240/480 3W /Disconnect | March 2010 |
| 3-4 (1/2) | | Photo Electric Cell Mounting Details | March 2010 |
| 3-4 (2/2) | | Photo Electric Cell Mounting Details | March 2010 |
| 3-5 (1/2) | | Type I and II Meter Pedestal Cabinet | March 2010 |
| 3-5 (2/2) | | Meter Pedestal Cabinet | December 2012 |
| 3-6 | | Type III Control Cabinet | March 2010 |
| 3-7 | | Pole Mount for Type III Control Cabinet | March 2010 |
| 3-8 (1/2) | | Pole Mount Details for Type III Control Cabinet | March 2010 |
| 3-8 (2/2) | | Pole Mount Details for Type III Control Cabinet | March 2010 |
| 3-9 (1/3) | | Type IV and V Control Cabinet Notes | March 2010 |
| 3-9 (2/3) | | Type IV Control Cabinet | March 2010 |
| 3-9 (3/3) | | Type V Control Cabinet | March 2010 |
| 3-10 | | Cabinet Extension Elevator Base | March 2010 |
| 3-11 | | Control Cabinet Mounted Service Enclosure | March 2010 |
| 3-12 (1/2) | | 120/240 or 240/480 Volt, Single Phase Utility Pull Section and Service Disconnect Details | March 2010 |
| 3-12 (2/2) | | 120/240 or 240/480 Volt, Single Phase Utility Pull Section and Service Disconnect Details | March 2010 |
| 3-13 (1/3) | | Traffic Signals & Lighting Model 345 Cabinet Details | March 2010 |
| 3-13 (2/3) | | Traffic Signals & Lighting Model 345 Cabinet Details | March 2010 |
| 3-13 (3/3) | | Traffic Signals & Lighting Model 345 Cabinet Cage Detail | March 2010 |
T.SL. 4
| Drawing Number | Drawing | Drawing Name | Date |
| 4-1 | | Type A Pole | April 2019 |
| 4-2 | | "Type "S" Pole" | April 2019 |
| 4-3 | | "Type "T" Pole" | April 2019 |
| 4-4 | | Type "S" and "T" Steel Twin Luminaire Mounting Bracket and Extensions | April 2019 |
| 4-5 | | Aluminum Type "S" Pole | April 2019 |
| 4-6 | | Aluminum Type "T" Pole | April 2019 |
| 4-7 | | Type "G" Pole | April 2019 |
| 4-8 | | Aluminum Type "G" Pole | April 2019 |
| 4-9 | | Aluminum Type "H" Pole | April 2019 |
| 4-10 | | Aluminum Type "I" Pole | April 2019 |
| 4-11 | | General Notes for Traffic Signal and Lighting Poles with Maximum Loading Case | April 2019 |
| 4-12 | | Type "J" Poles (25-J, 30-J, 35-J, and 40-J) With 25 ft to 40 ft Mast Arm Span Length | April 2019 |
| 4-13 | | Type "Q" Poles (25-QL, 30-QL, 35-QL, and 40-QL) with 25 ft to 40 ft Mast Arm Span Length with Luminaire | April 2019 |
| 4-14 | | Type "K" Poles (45-K, 50-K, and 55-K) with 45 ft to 55 ft Mast Arm Span Length | April 2019 |
| 4-15 | | Type "R" Poles (45-RL, 50-RL, and 5-RL) with 45 ft to 55 ft Mast Arm Span Length With Luminaire | April 2019 |
| 4-16 | | Type "V" Poles (60-V and 65-V) with 60 ft to 65 ft Mast Arm Span Length | April 2019 |
| 4-17 | | Type "W" Poles (60-WL and 65-WL) with 60 ft to 65 ft Mast Arm Span Length With Luminaire | April 2019 |
| 4-18 | | Pole Hand Hole Details | April 2019 |
| 4-19 | | Type "U" Pole (Elliptical Base) Details | April 2019 |
| 4-20 | | Type "U" Pole (Round Pole with Square Base) Notes | April 2019 |
| 4-21 | | Type "U" Pole (Round Pole with Square Base) Foundation Details | April 2019 |
| 4-22 | | Type "U" Pole (Round Pole with Square Base) Detail 1 | April 2019 |
| 4-23 | | Type "U" Pole (Round Pole with Square Base) Detail 2 | April 2019 |
| 4-24 | | Type "U" Pole (Round Pole with Square Base) Pipe Tenon Details | April 2019 |
| 4-25 | | Type "U" Pole (Round Pole with Square Base) Twin Luminaire Mounting Bracket Details | April 2019 |
| 4-26 | | Equipment Mounting Height Details | April 2019 |
| 4-27 | | Pedestrian Push Button Post "Type PB Pole" | April 2019 |
| 4-28 | | Pole Foundation Anchor Bolts | April 2019 |
| 4-29 | | Steel Mast Arm Details Luminaire and Signal Arms to 20' | April 2019 |
| 4-30 | | Aluminum Truss Arm Details Type G, H, and I Poles | April 2019 |
| 4-31 | | Signal Mast Arm Tenon Details | April 2019 |
| 4-32 | | Typical Highway Lighting Offsets in Cut and Fill Sections | April 2019 |
T.S. 5
| Drawing Number | Drawing | Drawing Name | Date |
| 5-0 | | Type 2 and 3 Cast Aluminum Break-Away Bases | April 2019 |
| 5-1 | | Type 2 Cast Aluminum Break-Away Base | April 2019 |
| 5-2 | | Type 3 Cast Aluminum Break-Away Base | April 2019 |
| 5-3 | | Installation Details for Pole Foundations with Type 2 and 3 Break-Away Bases | April 2019 |
T.S. 6
| Drawing Number | Drawing | Drawing Name | Date |
| 6-1 | | Type C Vehicle Detector Loops for Traffic Counters | March 2010 |
| 6-2 (1/3) | | Type SA and SB Speed/Vehicle Classification Systems | March 2010 |
| 6-2 (2/3) | | Type SA Speed/Vehicle Classification Systems | March 2010 |
| 6-2 (3/3) | | Type SB Speed/Vehicle Classification Systems | March 2010 |
| 6-3 | | Piezoelectric Weight Sensor and Loop Lane Layout | December 2012 |
| 6-4 (1/5) | | Detector Loops and Piezoelectric Sensor Details | December 2012 |
| 6-4 (2/5) | | Detector Loops and Piezoelectric Sensor Details | December 2012 |
| 6-4 (3/5) | | Detail A Piezoelectric Sensor Details | March 2015 |
| 6-4 (4/5) | | Detail B Detector Loop Details | December 2012 |
| 6-4 (5/5) | | Detector Loops and Piezoelectric Sensor Details | December 2012 |
| 6-5 | | Microloops for Speed/Vehicle Classification | March 2010 |
| 6-6 | | Quartz Piezoelectric Weight Sensor and Loop Lane Layout | March 2010 |
| 6-7 | | Traffic Data Collection Cabinet Installation Details | March 2010 |
| 6-8 | | Type MPD Cabinet Pole, Base and Foundation Installation Details | March 2010 |
T.S. 7
| Drawing Number | Drawing | Drawing Name | Date |
| 7-1 (1/5) | | Loop Detector Location Sawcut Patterns and Installation Details | March 2010 |
| 7-1 (2/5) | | Saw Cut and Coring Details | March 2010 |
| 7-1 (3/5) | | Saw Cut and Coring Details | March 2015 |
| 7-1 (4/5) | | Typical Detector Loop Lead-In Road to Pull Box Detail | March 2010 |
| 7-1 (5/5) | | Loop Detector Location and Installation Details | March 2010 |
| 7-2 | | Pre-Formed Loop Detectors for Ramp Metering and Counting | March 2010 |
| 7-3 | | Pre-Formed Loop Detectors in Bridge Deck | March 2010 |
| 7-4 | | Pre-Formed Loop Detectors in PCCP | March 2010 |
| 7-5 | | Typical Pre-Formed Loop Detector Stub-Out Detail | March 2010 |
T.S. 8
| Drawing Number | Drawing | Drawing Name | Date |
| 8-0 | | Traffic Signal Vehicle Face Assembly Requirements and Details | August 2019 |
| 8-1 | | Vehicle Traffic Signal Face Assembly | August 2019 |
| 8-2 | | Vehicle Traffic Signal Face Assembly | August 2019 |
| 8-4 (1/4) | | 12-Inch Vehicle Traffic Signal Housing/Section | October 2013 |
| 8-4 (2/4) | | 12-Inch Vehicle Traffic Signal Housing/Section Notes | January 2012 |
| 8-4 (3/4) | | Vehicle Traffic Signal Housing/Section Details | January 2012 |
| 8-4 (4/4) | | Visors for 8-Inch and 12-Inch Vehicle Traffic Signal Face Assemblies | March 2010 |
| 8-5 | | Flashing Beacon Signal Face Assembly | January 2012 |
| 8-6 | | LED Lamp for Programmed Visibility Signal | January 2012 |
| 8-7 (1/3) | | Pedestrian Signal Assembly Requirements and Details | January 2012 |
| 8-7 (2/3) | | Pedestrian Signal Assembly Housing | January 2012 |
| 8-7 (3/3) | | Pedestrian Signal Assembly Visor | January 2012 |
T.S. 9
| Drawing Number | Drawing | Drawing Name | Date |
| 9-0 (1/2) | | Mounting Assembly General Requirements | March 2010 |
| 9-0 (2/2) | | Mounting Assembly General Requirements | March 2010 |
| 9-1 | | Type I and II Mounting Assemblies | March 2010 |
| 9-2 | | Type III and IV Mounting Assemblies | March 2010 |
| 9-3 | | Type V Mounting Assembly | October 2013 |
| 9-4 | | Type VI Mounting Assembly | March 2010 |
| 9-5 | | Type VII Mounting Assembly | March 2010 |
| 9-6 | | Type VIII Mounting Assembly | March 2010 |
| 9-7 | | Type IX Mounting Assembly | March 2010 |
| 9-8 | | Type X Mounting Assembly | March 2010 |
| 9-9 | | Type XI Mounting Assembly | March 2010 |
T.S. 10
| Drawing Number | Drawing | Drawing Name | Date |
| 10-1 | | Miscellaneous Signal Mounting Parts | March 2010 |
| 10-2 | | Mast Arm Signal Plumbizer | March 2010 |
| 10-3 | | Signal Mounting Pole Plate Details | March 2010 |
| 10-4 | | Terminal Compartment, Side Mounted and Pole Top Mounted | March 2010 |
T.S. 11
| Drawing Number | Drawing | Drawing Name | Date |
| 11-1 | | Type I Pedestrian Push Button Housing Assembly | March 2015 |
| 11-2 | | Can Style Pedestrian Push Button | March 2015 |
T.S. 12
| Drawing Number | Drawing | Drawing Name | Date |
| 12-1 (1/3) | | Advance Warning Flasher Pole Detail | March 2010 |
| 12-1 (2/3) | | Advance Warning Flasher Pole Sign Mounting Details | March 2010 |
| 12-1 (3/3) | | Advance Warning Flasher Pole Detail | March 2010 |
T.S. 13
| Drawing Number | Drawing | Drawing Name | Date |
| 13-1 | | Sign Lighting Detail for Tubular Sign Structures | March 2010 |
| 13-2 | | Fuse Panel Details for Sign Lighting | March 2010 |
| 13-3 | | Placement of Lighting Fixtures for Overhead Signs | March 2015 |
T.S. 14
| Drawing Number | Drawing | Drawing Name | Date |
| 14-1 (1/3) | | High Pressure Sodium (HPS) Lamps | March 2010 |
| 14-1 (2/3) | | High Pressure Sodium (HPS) Lamps | March 2010 |
| 14-1 (3/3) | | High Pressure Sodium (HPS) Lamps | March 2010 |
| 14-2 | | Pedestrian Bridge Lighting Details | March 2010 |
T.S. 15
| Drawing Number | Drawing | Drawing Name | Date |
| 15-0 (1/3) | | General Notes | April 2019 |
| 15-0 (2/3) | | General Notes | April 2019 |
| 15-0 (3/3) | | General Notes | April 2019 |
| 15-1 (1/6) | | Steel Pole Typical Details | April 2019 |
| 15-1 (2/6) | | Steel Pole Foundation Details | April 2019 |
| 15-1 (3/6) | | Steel Pole Attachment Details | April 2019 |
| 15-1 (4/6) | | Wood Pole Typical Details | April 2019 |
| 15-1 (5/6) | | Wood Pole Typical Details | April 2019 |
| 15-1 (6/6) | | Typical Details | April 2019 |
| 15-2 | | Hanger and Balance Adjuster Typical Details | January 2012 |
| 15-3 (1/3) | | Signal Assembly Details | January 2012 |
| 15-3 (2/3) | | Conductor Entrance Heads Type A, B, and C | January 2012 |
| 15-3 (3/3) | | Aluminum Pipe Extension and Typical Details | January 2012 |
| 15-4 (1/3) | | Adjustable Sign Hanger Typical Details | January 2012 |
| 15-4 (2/3) | | Adjustable Sign Hanger Typical Details | January 2012 |
| 15-4 (3/3) | | Adjustable Sign Hanger Typical Details | January 2012 |
| 15-5 | | Adjustable Hanger Top and Extension Details | January 2012 |
| 15-6 | | Signal Tether Clamp Typical Details | January 2012 |
| 15-7 | | Pole Band Typical Details | January 2012 |
| 15-8 | | Weatherhead Typical Details | January 2012 |
Adot Traffic Signal And Lighting Standard Drawings
Source: https://azdot.gov/business/engineering-and-construction/traffic/signals-and-lighting-standard-sls-drawings
Posted by: solomonstrel1937.blogspot.com
0 Response to "Adot Traffic Signal And Lighting Standard Drawings"
Post a Comment